-40%

60A 230V Din Rail Adjustable Over Voltage and Under Voltage Protective Device

$ 10.54

Availability: 18 in stock
  • Over voltage proteciton:: 230V-300V (adjustable) (default: 270)
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Condition: New
  • Return shipping will be paid by: Buyer
  • Over current protection:: 1A-63A (adjustable) (default: 40A)
  • Custom Bundle: No
  • Country/Region of Manufacture: China
  • Display: Digital
  • Voltage Range: 60A 230V
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • MPN: Does not apply
  • Current Type: Universal
  • Under voltage protection:j: 210V-145V (adjustable) (default: 170V)
  • Brand: Tomzn
  • Reconnect time:: 3s-300s
  • Modified Item: No

    Description

    60A 230V Din Rail Adjustable Over Voltage And Under Voltage Protective Device
    Function:
    Under voltage protection 210V-145V (adjustable) (default: 170V)
    Over voltage proteciton 230V-300V (adjustable) (default: 270)
    Over current protection 1A-63A (adjustable) (default: 40A)
    Reconnect time (delay on time): 3s-300s (default: 30s)
    Voltage meter
    Ammeter
    Rated voltage: 220V; Frequency: 50Hz/60HZ
    Over current protection: 1A-63A (adjustable) (default: 40A)
    Under-voltage action switch-off value: 210V-145V (adjustable) (default: 170V)
    Over-voltage action switch-off value: 230V-300V (adjustable) (default: 270)
    Reconnect time (delay on time): 3s-300s (default: 30s)
    ​Error in real-time current, voltage : ≤5%
    60A 230V Din Rail Adjustable Over and Under Voltage Protective Device Protector Relay with Over Current Protection Voltmeter
    It would be an honor for us to realize your desires when you are shopping from our shop and to bring you the happiness you need. It will be a pleasure for us to answer all your questions and to make you satisfied with your online shopping.
    I. Application
    Over Voltage And Under Voltage Protective Device With Auto-Reclosing Function (OUPA) is an intelligent protector integrated with overvoltage protector, under-voltage protector, and over-current protector. In case of an over-voltage fault, under-voltage fault or over-current fault in line, this product can instantly power off to prevent electrical equipment from being burnt. The over-voltage, under-voltage and over-current values of this product can all be set up by yourself and can be adjusted on the basis of local practical condition.
    II. Product features
    2.1 In case of an over-voltage fault, under-voltage fault or over-current fault in single-phase line, the product can power off the line and can automatically restore connecting the line over a time delay after the voltage of the lien is recovered to normal condition.
    2.2 In the case of transient overvoltage in line, the product can protect the equipment from false operation.
    2.3 In case that the line subjects to unstable voltage or sudden power-off and power-on due to loosened connection and other faults, the product will disconnect the line.
    2.4 When fault voltage of the line reaches the peak, the product itself will not be damaged.
    2.5 Voltage protection range: 0—450V for 40A; 0—600V for 50A/63A.
    2.6 Impulse withstand voltage: 4KV (in compliance with safety standard for the electrical appliance of category III).
    III. Normal use and installation conditions
    3.1 Normal use conditions
    3.1.1  Ambient air temperature
    Ambient air temperature shall not be more than +55℃ and not less than -20℃ and the 24h average temperature shall not be more than +35℃.
    3.1.2 Altitude
    The altitude of the installation place shall not exceed 2000m.
    3.1.3 Atmospheric conditions
    3.1.3.1 Humidity
    The relative air humidity at installation place shall not be more than 50% when the ambient air temperature is +40℃; Relative humidity may be high under low-temperature condition. For instance, when the mean minimum temperature in the wettest month is +20℃, the mean maximum relative humidity in the month may reach 90%. Condensation produced due to temperature change shall be prevented by taking appropriate measure.
    3.1.3.2 Class of pollution: 3
    3.2  Installation conditions
    3.2.1 Protector can be vertically or horizontally mounted in the cabinet. If especially required, it is necessary to make a special order.
    3.2.2 Protector shall be mounted in medium without risk of explosion. In the medium, there shall be no gas and conductive dust which are sufficient to corrode metal and affect insulation effect.
    4.2.3 Protector shall be mounted in a place that may not be invaded by rain and snow.
    IV. Main technical parameters
    4.1.1 Rated voltage: 220V; Frequency: 50Hz/60HZ
    4.1.2 Rated current: 1A-63A (adjustable) (default: 40A)
    4.1.3 Under-voltage action switch-off value: 210V-145V (adjustable) (default: 170V)
    4.1.4 Over-voltage action switch-off value: 230V-300V (adjustable) (default: 270)
    4.1.5 Reconnect time (delay on time): 3s-300s (default: 30s)
    4.1.8 Cut off in 1s if over-voltage, under-voltage or over current.
    4.1.9 Power consumption≤2W
    4.1.10 Electrical and mechanical life≥100000 cycles
    4.1.11 Boundary dimension: 81×35×60mm
    4.1.12 Over-voltage and under-voltage action parameters and restoration parameters may be adjusted as required by the customer.
    4.1.13 This product is in over-entering and down-out mode.
    4.2.1  Characteristics and time of rated action
    4.2.2 Rated connecting capacity
    It refers to the current that can be reliably connected and disconnected under long-term continuous working condition of the protector.
    4.2.3 Rated over-current limit
    V. Product setting:
    5.1: Press and hold on the “set” key for 3s, entering into setting status;
    5.2: When overvoltage indicator lamp lights up, set up the overvoltage value by pressing the “up” key or “down” key to increase or decrease the overvoltage value which can be 230V-300V (default: 270V).
    5.3: Press the “set” key, when under-voltage indicator lamp lights up, set up the under-voltage value by pressing the “up” key or “down” key to increase or decrease the under-voltage value which can be 145V-210V, (default: 170V).
    5.4: Press the “set” key, when current indicator lamp lights up, set up the over-current value by pressing the “up” key or “down” key to increase or decrease the over-current value which can be 1A-63A (adjustable) (default: 40A).
    5.5: After the setting, stay for the 40s before powering on.
    5.6: Press the “up” key and “down” key together to restore factory setting.
    VII. Usage
    After being installed, the protector can be wired by the user. Wherein, a cross section of the wire shall be selected in accordance with standard applicable and on the basis of the rated current of the protector. Pay attention to the locations of incoming and outgoing wires and the phase sequence before powering on for use.
    VIII. Notes
    8.1 The input and output shall be corrected connected on the basis of the product marking. (Wherein, the load current shall be less than the protective current of the product. )
    8.2 Neutral line N cannot be improperly connected and shall be reliably wired; otherwise, the protector may not work normally.
    8.3 Before powering on, please carefully check whether the wiring is correct, whether the load matches with the protective current of the product and whether the binding screw is tightened; otherwise, the product may be damaged.
    8.4 After powering on the product, don’t touch any live part to avoid electric shock.
    8.5 This product shall be combined with microcircuit breaker to play a role of short-circuit protection; otherwise, the product may not be able to realize load limit protection in the case that input or load end of the product appears short circuit.
    8.6 As the product has automatic reset function after the product plays the role of protection and acts, it is necessary to remove the load (electric appliance) and check the circuit; otherwise the product will be frequently connected and disconnected to the load. Finally, the product or its circuit may be burnt due to frequent overload connection and disconnection for a long time.