Description
HoldPeak Voltage Tester LED LCD Display AC/DC Voltage Continuity test 12-690V USHP-38A 12~690V Three Phase Sequence Rotation Indicator Tester hecker LED Alarm
Specification
Brand: Holdpeak
Model:HP-38A
Material: ABS
*LED Indication Voltage Test:
Voltage Range: 12-690V AC/DC
Nominal Voltage Europe: 12/24/50/120/230/400/690V
Tolerance(Threshold Voltage)Light on at more than: 7±5V(50V LED), 18±5V(24V LED), 37.5±5V(50V LED), 75%±5% of nominal voltage(120/230/400/690V LED)
*LCD Display Voltage Test:
Range/Resolution: 7-690V/1V(Auto-range)
Accuracy(23±5C): (3%+3) or 5V
Over Range Indication: All Voltage LED light up
Response Time: <1s at 90% of each voltage
*High Voltage Indication:
Voltage Range 50-690V AC/DC
*Phase Rotation Test:
System: Three-phase 4-Wire system AC
Frequency: 50Hz~60Hz
Phase Range: 120±5 degree
*Continuity Test:
Detection Range: 0-550KΩ(±2O0K)
Test Current: Approx. 1.5uA(battery 3V 0Q)
*Reference Condition:
Battery: 2 * 1 5V(IEC LR03 1 5Vx2)
Temperature: -10~55°C Operation, -20~6O°C(Storage No condensation)
Humidity: Max 85% RH
Altitude: up to 2000m
Operating Temperature: -10~55°C / 14~131°F
Operating Humidity: ≤85% RH
Storage Temperature: -20~60°C / -4~140°F
Storage Humidity: ≤85% RH
Power Supply: IEC LR03 1.5V *2( not included in packaged)
Item Size: Approx. 25 * 5.5 * 2cm / 9.84 * 2.17 * 0.79in
Model
HP-38A
Voltage Test
LCD Voltage Range
12-690V AC/DC
Accuracy(23±5℃)
±(3%+3)
Resolution
1V
LED Voltage Range
12-690V AC/DC
Tolerance(Threhold Voltage)
Light on at more than
:7±5V(12V LED):18±5V(24V LED)
:37.5±5V(50V LED):75%±5% of norminal voltage
(120/230/400/690V LED)
High voltage indication(LED indicator)
Voltage Range
50-690V AC/DC
Phase Range
120±5 degree
Phase rotation test
Detection Range
0-750kΩ
Test Current
Approx. 1.5μA
IP Rating
IP64
Precautions
1 Never take measurements on a circuit in which the electrical potential exceeds 690V.(When the measured voltage exceeds 690V, all the voltage LED displays will light up)
2 Do not attempt to take measurements in the presence of flammable gasses, as the use of the.
3 Never attempt to use the instrument if the surface of your hands are wet. (Do not use in rain.)
4 Keep your hands and fingers behind the barriers during measurements.
5 Never unlock and open the battery case during measurements.
6 Verify proper operation on a known source before taking action as a result of the indication.
7 Never attempt to make any measurement in any abnormal conditions, such as a broken case.or exposed metal parts are present on the instrument or test probes.
8 Do not make any modification to the instrument.
9 Take extreme caution when live circuit LED flashes or lights up.
10 Correct indication of LEDs is only guaranteed within a temperature range of -10℃ up to 55℃(<85%RH).instrument may cause sparking, which could lead to an explosion.
Package List:
1 * Voltage Tester with Test Probes
1 * User Manual
Brand
HoldPeak
Display
Digital
Features
Backlight, Auto Power Off, Low battery Indication, Phase Rotation Test
Country/Region of Manufacture
China
IP Rating
IP64
MPN
HP-38A
Form Factor
Handheld
Test/Measurement Functions
Voltage test,3 Phase Rotation Test,Continuity Test
Measurement Category
CAT III
System
Three-Phase 4 wire system AC
Voltage Range
12-690V AC/DC